What does Error code 112 mean?
This article explains error code 112
 
Applicable platform:
This error code can be found on chargers using the below platform(s):
  • AHP (Alfen Hardware Platform) ≥ FW Version 2.3.0
 
Error code 1xx | Error codes inside charge point
Error codes starting with '1' indicate that the most likely cause for the error is related to an issue inside the charger.
 

Error code:
112
 

Error message on display:
Not able to charge. Please call for support.

Possible Cause:
Internal error.
Unexpected or no voltage on output of power board or power interrupted by internal RCD when the station is configured to be Eichrecht compliant.

Possible solutions:
Contact your installation engineer.
- Either internal RCD (Type A:30mA AC) tripped.
- Check Socket Board

OCPP Statusnotification:
Info field: Power/RCD trip error, local engineer reset needed
OCPP 1.5:
OCPP 1.6/2.0.1: PowerSwitchFailure